Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Slaughter Estate Unit CO/sub 2/ pilot reservoir description via a black oil model waterflood history match

Conference · · Soc. Pet. Eng. AIME, Pap.; (United States)
OSTI ID:6133059

Amoco Production Company is conducting a tertiary miscible gas pilot in the Slaughter Estate Unit, Hockley County, Texas. The pilot consists of two normal five-spot patterns which encompass an area of 12.3 acres (49.8 Mm/sup 2/) and is located in a region of the unit that is undergoing an active waterflood. The pilot wells were drilled in 1972 in an area of the unit that was under volumetric depletion. A pilot waterflood was then initiated in November 1972. A well-established secondary decline was obtained in the pilot in 1976 and acid gas (72% CO/sub 2/ and 28% H/sub 2/S) was then initiated. The pilot objectives are to determine primary plus secondary and tertiary oil recovery and to obtain a quantitative interpretation of the acid gas displacement process. A good reservoir description is required to meet these objectives since the tertiary performance is influenced by both reservoir heterogeneities and variables associated with the acid gas displacement process. It was determined that the Slaughter Estate Unit tertiary pilot had an original oil-in-place of 642,400 STB (102 133 m/sup 3/). A waterflood prediction using the reservoir description described in this paper indicates that an ultimate primary plus secondary recovery of 48.8% OOIP would have been obtained from the pilot if waterflood operations had been continued to an abandonment water cut of 98%. Based on this prediction, it was established that the tertiary oil recovery due to the miscible acid gas process was 15.5% OOIP as of October 21, 1981 (JMT)

OSTI ID:
6133059
Report Number(s):
CONF-820419-
Journal Information:
Soc. Pet. Eng. AIME, Pap.; (United States), Journal Name: Soc. Pet. Eng. AIME, Pap.; (United States); ISSN SEAPA
Country of Publication:
United States
Language:
English

Similar Records

Slaughter estate unit tertiary miscible gas pilot reservoir description
Journal Article · Tue May 01 00:00:00 EDT 1984 · J. Pet. Technol.; (United States) · OSTI ID:5357894

Slaughter Estate Unit CO/sub 2/ pilot reservoir description via a black oil model waterflood history match
Conference · Thu Dec 31 23:00:00 EST 1981 · Soc. Pet. Eng. AIME, Pap.; (United States) · OSTI ID:6222113

Slaughter estate unit tertiary pilot performance
Journal Article · Sun Feb 28 23:00:00 EST 1982 · J. Pet. Technol.; (United States) · OSTI ID:5238369