Ring-magnetron ionizer for polarized negative-ion sources
It has been realized for some time that the use of the charge exchange reaction of negative deuterium ions with polarized neutral hydrogen yielding neutral deuterium and polarized negative hydrogen ions to produce polarized H/sup -/ ions could be very efficient. While intense H/sup -//D/sup -/ ion sources exist, one encounters space charge problems when trying to put this scheme into practice. In this paper, a simple method, which uses a self-extracted D/sup -/ beam from a ring magnetron source, is proposed. The basic idea is presented, approximate numbers are given and the expected intensity is estimated. The method not only offers improvement in intensity, but equally important, improvements in reliability and lifetime.
- Research Organization:
- Brookhaven National Lab., Upton, NY (USA)
- DOE Contract Number:
- AC02-76CH00016
- OSTI ID:
- 6126192
- Report Number(s):
- BNL-33272; CONF-830591-3; ON: DE83014763
- Resource Relation:
- Conference: Polarized ion workshop, Vancouver, Canada, 23 May 1983
- Country of Publication:
- United States
- Language:
- English
Similar Records
Efficient ionizer for polarized H/sup -/ formation
Progress in the development of steady state negative ion sources for fusion applications
Related Subjects
HYDROGEN 1 MINUS BEAMS
BEAM PRODUCTION
POLARIZED BEAMS
ATOMIC BEAMS
BEAM EXTRACTION
BROOKHAVEN AGS
CHARGE EXCHANGE
ION SOURCES
MAGNETRONS
ACCELERATORS
BEAMS
CYCLIC ACCELERATORS
ELECTRON TUBES
ELECTRONIC EQUIPMENT
EQUIPMENT
ION BEAMS
MICROWAVE EQUIPMENT
MICROWAVE TUBES
SYNCHROTRONS
430301* - Particle Accelerators- Ion Sources