Remedies for PWR (pressurized water reactor) recirculating steam generator tube aging
Conference
·
OSTI ID:6120379
Pressurized water reactor (PWR) steam generator tubes form well over one-half of the primary system pressure boundary and have experienced significant aging degradation at some plants. Tube failures have caused contamination of the secondary coolant by the primary coolant, and radiological releases to the environment when atmospheric relief valves were actuated. Degraded steam generator tubes may fail during a severe accident and allow radioactive material to bypass containment. Simultaneous rupture of several tubes may lead to a major plant temperature and pressure transient with potential impact on the structural integrity of various components in the system. Tube leakages result in unscheduled plant outages when the leakage rate exceeds acceptable limits. Finally, repair and replacement associated with steam generators account for much of the personnel radiation exposure (manrems) at PWR plants. Therefore, industry has developed various remedies for steam generator tube aging. This paper evaluates the effectiveness of current remedies used to reduce aging damage to recirculating type steam generator tubes (Shah and MacDonald, 1988). The following topics are discussed: degradation mechanisms, mitigation techniques, repair methods, and conclusions and recommendations. 11 refs., 2 tabs.
- Research Organization:
- EG and G Idaho, Inc., Idaho Falls, ID (USA)
- DOE Contract Number:
- AC07-76ID01570
- OSTI ID:
- 6120379
- Report Number(s):
- EGG-M-88422; CONF-890855-27; ON: DE89011113
- Country of Publication:
- United States
- Language:
- English
Similar Records
Solving chemical and mechanical problems of PWR steam generators
Steam generator tube failures
Semiscale steam-generator tube-rupture test results. [PWR]
Journal Article
·
Wed Jul 01 00:00:00 EDT 1987
· Chem. Eng. Prog.; (United States)
·
OSTI ID:6441613
Steam generator tube failures
Technical Report
·
Sun Mar 31 23:00:00 EST 1996
·
OSTI ID:236258
Semiscale steam-generator tube-rupture test results. [PWR]
Conference
·
Fri Dec 31 23:00:00 EST 1982
·
OSTI ID:5563759
Related Subjects
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS
210200* -- Power Reactors
Nonbreeding
Light-Water Moderated
Nonboiling Water Cooled
AGING
BOILERS
CHEMICAL REACTIONS
CORROSION
CRACKS
FAILURES
INTERGRANULAR CORROSION
MITIGATION
PITTING CORROSION
PWR TYPE REACTORS
REACTORS
RECOMMENDATIONS
REPAIR
STEAM GENERATORS
STRESS CORROSION
TUBES
VAPOR GENERATORS
WATER COOLED REACTORS
WATER MODERATED REACTORS
210200* -- Power Reactors
Nonbreeding
Light-Water Moderated
Nonboiling Water Cooled
AGING
BOILERS
CHEMICAL REACTIONS
CORROSION
CRACKS
FAILURES
INTERGRANULAR CORROSION
MITIGATION
PITTING CORROSION
PWR TYPE REACTORS
REACTORS
RECOMMENDATIONS
REPAIR
STEAM GENERATORS
STRESS CORROSION
TUBES
VAPOR GENERATORS
WATER COOLED REACTORS
WATER MODERATED REACTORS