A gas-turbine topping-cycle cogeneration system was developed to specifically meet the needs of industrial cogenerators in the 2-10 MW(sub e) range. The steam-injected cogeneration system was installed in the GM/Hydramatic plant in Warren, Michigan. Operation of the cogeneration system commenced in June of 1988. The cogeneration system was installed with sufficient instrumentation to allow monitoring of the performance for at least a one-year period. Two areas of interest are the effects of steam injection on the NOx and carbon monoxide emission levels and the performance of the passive feedwater cleanup system.