University of Washington electrostatic scrubber tests at a steel plant. Phase report, June 1976--June 1978
Technical Report
·
OSTI ID:6100684
The report gives results of a demonstration of the effectiveness of a 1700 cu m/hr (1000 acfm) University of Washington (UW) Electrostatic Spray Scrubber in controlling fine particle emissions from an electric-arc steel furnace. The two-stage portable pilot plant operates by combining oppositely charged aerosol particles and water droplets in two water spray towers. Aerosol charging sections (coronas) with negative polarity precede each spray tower. Simultaneous inlet and outlet source tests utilizing UW Cascade Impactors--Mark V for the inlet and Mark III for the outlet--provided both size-dependent and overall mass basis particle collection efficiency information. Measured overall particle collection efficiencies ranged from 58.8 to 99.5%, depending on the electrostatic scrubber operating conditions and on the inlet particle size distribution. Tabular and graphic data is presented illustrating the effects of the corona specific plate area, liquid to gas flow rate ratio, magnitudes of particle and droplet charging voltages, and electrostatic polarities on the overall particle collection efficiencies and on the particle collection efficiency as a function of particle size.
- Research Organization:
- Washington Univ., Seattle (USA). Dept. of Civil Engineering
- OSTI ID:
- 6100684
- Report Number(s):
- PB-288307
- Country of Publication:
- United States
- Language:
- English
Similar Records
University of washington electrostatic scrubber tests at a coal-fired power plant. Final report, June 1977-October 1978
University of Washington electrostatic scrubber tests: combined particulate and SO/sub 2/ control. Final report Jun 78-Aug 79
University of Washington electrostatic spray scrubber evaluation. Final report, Dec 1974--Dec 1975
Technical Report
·
Thu Nov 30 23:00:00 EST 1978
·
OSTI ID:5861614
University of Washington electrostatic scrubber tests: combined particulate and SO/sub 2/ control. Final report Jun 78-Aug 79
Technical Report
·
Wed Oct 31 23:00:00 EST 1979
·
OSTI ID:6686733
University of Washington electrostatic spray scrubber evaluation. Final report, Dec 1974--Dec 1975
Technical Report
·
Wed Mar 31 23:00:00 EST 1976
·
OSTI ID:7231381
Related Subjects
42 ENGINEERING
424000* -- Engineering-- Pollution Control Equipment-- (1980-1989)
ALLOYS
EFFICIENCY
ELECTROSTATICS
EQUIPMENT
FLUE GAS
GASEOUS WASTES
INDUSTRIAL PLANTS
INDUSTRY
IRON ALLOYS
IRON BASE ALLOYS
METAL INDUSTRY
PARTICLES
PERFORMANCE TESTING
POLLUTION CONTROL EQUIPMENT
SCRUBBERS
STEELS
TESTING
WASTES
424000* -- Engineering-- Pollution Control Equipment-- (1980-1989)
ALLOYS
EFFICIENCY
ELECTROSTATICS
EQUIPMENT
FLUE GAS
GASEOUS WASTES
INDUSTRIAL PLANTS
INDUSTRY
IRON ALLOYS
IRON BASE ALLOYS
METAL INDUSTRY
PARTICLES
PERFORMANCE TESTING
POLLUTION CONTROL EQUIPMENT
SCRUBBERS
STEELS
TESTING
WASTES