Temporal fluctuations of formaldehyde levels inside residences

Technical Report ·
OSTI ID:6100516
Excursions in the levels of formaldehyde were measured inside three houses. These were a 10-y-old home, a 3 y-old home prefitted with urea-formaldehyde foam insulation (UFFI), and a 2-y-old energy-efficient home. Measurements of formaldehyde were made using active and passive air-sampling devices with subsequent colorimetric analysis by the pararosaniline procedure. The variation of diurnal formaldehyde concentrations inside each house varied by up to a factor of two. Over the course of a year, the formaldehyde concentration within the 3-y-old UFFI house varied by an order of magnitude. These changes appeared to correlate with factors such as changes in the temperature, weather, and occupant activity. Inside the 2-y-old house the effects on formaldehyde levels of increased ventilation rate and the operation of a small charcoal-based air cleaner were studied. The results suggest that formaldehyde levels were not inversely proportional to the air exchange rate and that the air cleaner tested were ineffective.
Research Organization:
Oak Ridge National Lab., TN (USA)
DOE Contract Number:
W-7405-ENG-26
OSTI ID:
6100516
Report Number(s):
CONF-830338-4; ON: DE83009788
Country of Publication:
United States
Language:
English