Development of a standard methodology for optimizing remote visual display for nuclear-maintenance tasks
Conference
·
OSTI ID:6085292
The aim of the present study is to develop a methodology for optimizing remote viewing systems for a fuel recycle facility (HEF) being designed at Oak Ridge National Laboratory (ORNL). An important feature of this design involves the Remotex concept: advanced servo-controlled master/slave manipulators, with remote television viewing, will totally replace direct human contact with the radioactive environment. Therefore, the design of optimal viewing conditions is a critical component of the overall man/machine system. A methodology has been developed for optimizing remote visual displays for nuclear maintenance tasks. The usefulness of this approach has been demonstrated by preliminary specification of optimal closed circuit TV systems for such tasks.
- Research Organization:
- Oak Ridge National Lab., TN (USA); Oak Ridge Associated Universities, Inc., TN (USA)
- DOE Contract Number:
- W-7405-ENG-26
- OSTI ID:
- 6085292
- Report Number(s):
- CONF-811032-2; ON: DE82001462
- Country of Publication:
- United States
- Language:
- English
Similar Records
HEF mockup at Los Alamos
Remotex: a new concept for efficient remote operation and maintenance in nuclear fuel reprocessing. [Hot Experimental Facility (HEF)]
Long-range, high-speed remote handling at the CERN 26-GeV proton synchrotron
Conference
·
Thu Dec 31 23:00:00 EST 1981
·
OSTI ID:5189905
Remotex: a new concept for efficient remote operation and maintenance in nuclear fuel reprocessing. [Hot Experimental Facility (HEF)]
Conference
·
Mon Dec 31 23:00:00 EST 1979
·
OSTI ID:5116370
Long-range, high-speed remote handling at the CERN 26-GeV proton synchrotron
Conference
·
Tue Dec 31 23:00:00 EST 1974
· Conf. Remote Syst. Technol., Proc., v. 23, pp. 247-251
·
OSTI ID:4032611