Operational experience with compressed geometry acceleration tubes in the Oak Ridge 25URC tandem accelerator
Conference
·
OSTI ID:6083275
Installation of compressed geometry acceleration tubes and other associated modifications have increased the effective voltage capability of the Oak Ridge 25URC tandem accelerator by about 3 MV. Since mid-September 1988, the accelerator has been operated routinely at terminal potentials up to 24 MV and occasionally near 25 MV. In 3500 hours of full-column operation, including 1100 hours at potentials about 22 MV, no significant spark-included damage was observed. Some considerations related to further improvements in voltage performance are discussed. 7 refs., 5 figs.
- Research Organization:
- Oak Ridge National Lab., TN (USA)
- DOE Contract Number:
- AC05-84OR21400
- OSTI ID:
- 6083275
- Report Number(s):
- CONF-8905141-2; ON: DE89014071
- Country of Publication:
- United States
- Language:
- English