Partial discharge inception and extinction studies in polymer film structures impregnated with compressed SF/sub 6/ gas
Conference
·
OSTI ID:6072463
New concepts for a gas insulated transformer include the following turn-to-turn structure for the transformer windings: sheet conductor (aluminum foil); polymer film insulation (Mylar film); and pressurized SF/sub 6/ gas (impregnating the structure). A previous study of this structure compared the 60 Hz discharge inception and breakdown performance of model windings using 0.0125 and 0.0233 mm thick polymer films. The present experimental investigation is part of a larger program evaluating the effect of different parameters (gas pressure, voltage waveform, conditioning effects, etc.) on the performance of this insulation system. Six-inch size models, featuring multiple samples wound concentrically, were tested. A new winding apparatus was designed and built specifically for the construction of these models. The test equipment, procedures, and results are discussed. The results showed that good consistency was achieved in the discharge and breakdown performance of 6-in. size coils wound on the specially-designed winding apparatus; normal probability plots indicate a single mode of breakdowns, partly determined by the quality of the conductor edge finish and partly by chance residual particles; the validity of using multiple-sample test coils was demonstrated; there has been no evidence for conditioning effects on discharge behavior in tests in air or SF/sub 6/ gas using coils constructed with precision slit aluminum; and discharge inception and extinction are affected by gas pressure in short-time tests, but breakdown is unaffected.
- Research Organization:
- General Electric Co., Schenectady, NY (USA). Research and Development Center
- DOE Contract Number:
- AC01-77ET29069
- OSTI ID:
- 6072463
- Report Number(s):
- CONF-811016-2; ON: DE81029140
- Country of Publication:
- United States
- Language:
- English
Similar Records
Partial discharge inception and breakdown studies on model sheet-wound, compressed SF/sub 6/ gas-impregnated, polymer film-insulated windings
Evaluation of advanced technologies for power transformers. Final report, Part 2, June 1, 1979-June 30, 1981
Conceptual study of a SF/sub 6/ impregnated high voltage capacitor bank. Final report
Conference
·
Mon Dec 31 23:00:00 EST 1979
·
OSTI ID:5546034
Evaluation of advanced technologies for power transformers. Final report, Part 2, June 1, 1979-June 30, 1981
Technical Report
·
Tue Jun 30 00:00:00 EDT 1981
·
OSTI ID:6456331
Conceptual study of a SF/sub 6/ impregnated high voltage capacitor bank. Final report
Technical Report
·
Sat May 01 00:00:00 EDT 1982
·
OSTI ID:6811093
Related Subjects
200300* -- Electric Power Engineering-- Power Transmission & Distribution-- (-1989)
24 POWER TRANSMISSION AND DISTRIBUTION
AIR
BREAKDOWN
DATA
DIELECTRIC MATERIALS
ELECTRIC DISCHARGES
ELECTRICAL EQUIPMENT
ELECTRICAL INSULATION
ENERGY SYSTEMS
EQUIPMENT
EXPERIMENTAL DATA
FABRICATION
FILMS
FLUIDS
FLUORIDES
FLUORINE COMPOUNDS
GASES
HALIDES
HALOGEN COMPOUNDS
INFORMATION
MATERIALS
NUMERICAL DATA
PERFORMANCE TESTING
POLYMERS
POWER SYSTEMS
PRESSURE DEPENDENCE
SULFUR COMPOUNDS
SULFUR FLUORIDES
TESTING
TRANSFORMERS
24 POWER TRANSMISSION AND DISTRIBUTION
AIR
BREAKDOWN
DATA
DIELECTRIC MATERIALS
ELECTRIC DISCHARGES
ELECTRICAL EQUIPMENT
ELECTRICAL INSULATION
ENERGY SYSTEMS
EQUIPMENT
EXPERIMENTAL DATA
FABRICATION
FILMS
FLUIDS
FLUORIDES
FLUORINE COMPOUNDS
GASES
HALIDES
HALOGEN COMPOUNDS
INFORMATION
MATERIALS
NUMERICAL DATA
PERFORMANCE TESTING
POLYMERS
POWER SYSTEMS
PRESSURE DEPENDENCE
SULFUR COMPOUNDS
SULFUR FLUORIDES
TESTING
TRANSFORMERS