Tower Shielding Reactor II design and operation report. Vol. 3. Assembling and testing of the control mechanism assembly
The mechanisms that are operated to control the reactivity of the Tower Shielding Reactor II(TSR-II) are mounted on a Control Mechanism Housing (CMH) that is centered inside the reactor core. The information required to procure, fabricate, inspect, and assemble a CMH is contained in the ORNL engineering drawings listed in the appropriate sections. The components are fabricated and inspected from these drawings in accordance with a Quality Assurance Plan and a Manufacturing Plan. The material in this report describes the acceptance and performance tests of CMH subassemblies used ty the Tower Shielding Facility (TSF) staff but it can also be used by personnel fabricating the components. This information which was developed and used before the advent of the formalized QA Program and Manufacturing Plans evolved during the fabrication and testing of the first five CMHs.
- Research Organization:
- Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
- DOE Contract Number:
- W-7405-ENG-26
- OSTI ID:
- 6071107
- Report Number(s):
- ORNL/TM-2893(Vol.3); TRN: 79-019289
- Country of Publication:
- United States
- Language:
- English
Similar Records
GCFR grid plate shield design confirmation experiment
Removal site evaluation report on the Tower Shielding Facility at Oak Ridge National Laboratory, Oak Ridge, Tennessee
Related Subjects
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS
TSR-2 REACTOR
REACTOR CONTROL SYSTEMS
FABRICATION
INSPECTION
PERFORMANCE TESTING
CONTROL SYSTEMS
REACTORS
RESEARCH AND TEST REACTORS
RESEARCH REACTORS
TEST REACTORS
TESTING
WATER COOLED REACTORS
WATER MODERATED REACTORS
220400* - Nuclear Reactor Technology- Control Systems
220600 - Nuclear Reactor Technology- Research
Test & Experimental Reactors