Major facility overhauls at LAMPF
Conference
·
· IEEE Trans. Nucl. Sci.; (United States)
OSTI ID:6066724
The Clinton P. Anderson Meson Physics Facility (LAMPF) is a linear proton accdLerator designed to operate at 800 MeV and 1.0 mA. It has been operating at power levels above 200 microamperes since February of 1976 and now routinely operates near the design level. This paper outlines the problems encountered with the original target cell components, the repairs required since 1976, and specifically details the steps involved in the complete replacement of the vital target cell components. These components include target boxes, collimators, main beam line magnets, and the front-end magnets of the secondary beam lines. The A-2 target cell was replaced in the spring of 1983 and the A-1 target cell was replaced in the spring of 1984. Both have operated satisfactorily since their completion, with only minor difficulties. The overhaul and total component replacement in the beam stop area (A-6) was completed in early May 1985 and has just been placed in operation. The upgrade, in addition to the replacement of the beam stop and the vacuum-to-air window with state-of-the-art designs, provides a greatly increased capability of both proton and neutron irradiation of materials.
- Research Organization:
- Los Alamos National Laboratory, Los Alamos, NM
- OSTI ID:
- 6066724
- Report Number(s):
- CONF-850504-
- Conference Information:
- Journal Name: IEEE Trans. Nucl. Sci.; (United States) Journal Volume: NS-32:5
- Country of Publication:
- United States
- Language:
- English
Similar Records
Major facility overhauls at LAMPF
Recent advances in remote handling at LAMPF
Recent advances in remote handling at LAMPF
Conference
·
Mon Dec 31 23:00:00 EST 1984
·
OSTI ID:5735349
Recent advances in remote handling at LAMPF
Conference
·
Mon Dec 31 23:00:00 EST 1984
·
OSTI ID:5613619
Recent advances in remote handling at LAMPF
Conference
·
Tue Oct 01 00:00:00 EDT 1985
· IEEE Trans. Nucl. Sci.; (United States)
·
OSTI ID:6076793
Related Subjects
43 PARTICLE ACCELERATORS
430303* -- Particle Accelerators-- Experimental Facilities & Equipment
ACCELERATORS
BEAM CURRENTS
CURRENTS
ENERGY RANGE
LAMPF LINAC
LINEAR ACCELERATORS
MAINTENANCE
MESON FACTORIES
MEV RANGE
MEV RANGE 100-1000
MICRO AMP BEAM CURRENTS
MILLI AMP BEAM CURRENTS
PERFORMANCE
REPAIR
TARGETS
430303* -- Particle Accelerators-- Experimental Facilities & Equipment
ACCELERATORS
BEAM CURRENTS
CURRENTS
ENERGY RANGE
LAMPF LINAC
LINEAR ACCELERATORS
MAINTENANCE
MESON FACTORIES
MEV RANGE
MEV RANGE 100-1000
MICRO AMP BEAM CURRENTS
MILLI AMP BEAM CURRENTS
PERFORMANCE
REPAIR
TARGETS