Recent upgrading of the Brookhaven double MP facility and plans for the future
Conference
·
OSTI ID:6052935
The recent improvements of the Brookhaven tandems have resulted in operation at higher terminal voltages for both accelerators. MP6 can now operate at about -11 MV when used as an injector for MP7. The terminal voltage of MP7 can easily reach 16 MV, and 16.5 MV operation has been used for one experiment.
- Research Organization:
- Brookhaven National Lab., Upton, NY (USA)
- DOE Contract Number:
- AC02-76CH00016
- OSTI ID:
- 6052935
- Report Number(s):
- BNL-32929; CONF-821066-5; ON: DE83011641
- Country of Publication:
- United States
- Language:
- English
Similar Records
Brookhaven Double MP Facility - recent developments and plans for the future
UPGRADE AND OPERATION OF THE BNL TANDEMS FOR RHIC INJECTION.
Brookhaven National Laboratory Tandem Facility
Conference
·
Fri Dec 31 23:00:00 EST 1982
·
OSTI ID:5824546
UPGRADE AND OPERATION OF THE BNL TANDEMS FOR RHIC INJECTION.
Conference
·
Mon Jun 18 00:00:00 EDT 2001
·
OSTI ID:783984
Brookhaven National Laboratory Tandem Facility
Conference
·
Fri Dec 31 23:00:00 EST 1982
·
OSTI ID:5362451
Related Subjects
43 PARTICLE ACCELERATORS
430303* -- Particle Accelerators-- Experimental Facilities & Equipment
ACCELERATORS
BNL
ELECTRIC POTENTIAL
ELECTROSTATIC ACCELERATORS
ENERGY RANGE
MEV RANGE
MODIFICATIONS
NATIONAL ORGANIZATIONS
PERFORMANCE
TANDEM ELECTROSTATIC ACCELERATORS
US AEC
US DOE
US ERDA
US ORGANIZATIONS
VAN DE GRAAFF ACCELERATORS
430303* -- Particle Accelerators-- Experimental Facilities & Equipment
ACCELERATORS
BNL
ELECTRIC POTENTIAL
ELECTROSTATIC ACCELERATORS
ENERGY RANGE
MEV RANGE
MODIFICATIONS
NATIONAL ORGANIZATIONS
PERFORMANCE
TANDEM ELECTROSTATIC ACCELERATORS
US AEC
US DOE
US ERDA
US ORGANIZATIONS
VAN DE GRAAFF ACCELERATORS