Hydraulic testing of crushed Bandelier Tuff

Technical Report ·
OSTI ID:60528

This report emphasizes large-scale testing, using the instantaneous profile method, for determination of unsaturated hydraulic conductivity. To allow for comparison, unsaturated conductivity was measured in the laboratory using the pressure plate method. Laboratory techniques and large-scale testing for determination of unsaturated hydraulic conductivity using the instantaneous profile method have been studied. It was found that in both cases the hydraulic conductivity could best be expressed as a power function of the water ratio by volume. Both graphical and analytical methods were used to analyze the moisture and tensiometric data provided by the instantaneous profile method and led to the determination of the hydraulic conductivity values. 13 references, 6 figures, 9 tables.

Research Organization:
Los Alamos National Lab., NM (United States)
DOE Contract Number:
W-7405-ENG-36
OSTI ID:
60528
Report Number(s):
LA--10037-MS; ON: DE84011022
Country of Publication:
United States
Language:
English

Similar Records

Determination of hydraulic conductivity in crushed Bandelier Tuff
Technical Report · Wed Oct 31 23:00:00 EST 1979 · OSTI ID:5798167

The unsaturated hydraulic characteristics of the Bandelier Tuff
Technical Report · Fri Sep 01 00:00:00 EDT 1995 · OSTI ID:109668

Unsaturated hydraulic conductivity of two compacted barrier soils
Journal Article · Mon Jul 01 00:00:00 EDT 1996 · Journal of Geotechnical Engineering · OSTI ID:390056