Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Performance evaluations of 50 MVA airgap winding stator for superconducting generator

Journal Article · · IEEE Trans. Power Electronics; (United States)
DOI:https://doi.org/10.1109/60.17921· OSTI ID:6044490

This paper describes structural features of a trial-manufactured airgap winding stator for a 50 MVA superconducting generator and results of various characteristic tests. The stator has an improved winding section, strengthened against electromagnetic force and smaller sized, due to use of a four-layer water cooled helical airgap armature winding. Peculiarities as to the flux distribution and airgap winding electromagnetic force of the generator during operation were clarified, based on a three-dimensional magnetic field analysis. The structure of this airgap winding stator is sufficiently durable for use in the 50 MVA superconducting generator.

Research Organization:
Hitachi Research Lab., Hitachi, Ltd., Hitachi-shi, Ibaraki-ken (JP)
OSTI ID:
6044490
Journal Information:
IEEE Trans. Power Electronics; (United States), Journal Name: IEEE Trans. Power Electronics; (United States) Vol. 4:2; ISSN ITCNE
Country of Publication:
United States
Language:
English

Similar Records

Superconducting rotor development for a 50 MVA generator
Journal Article · Sun Jul 01 00:00:00 EDT 1984 · IEEE Trans. Power Appar. Syst.; (United States) · OSTI ID:6023804

Thermal stress analysis and design of the stator of a 300 MVA superconducting generator
Journal Article · Mon Sep 01 00:00:00 EDT 1986 · IEEE Trans. Power Electronics; (United States) · OSTI ID:5262547

Development of the stator for a 20-MVA superconducting generator
Conference · Thu Dec 31 23:00:00 EST 1981 · Adv. Cryog. Eng.; (United States) · OSTI ID:6263198