OSTI ID:6044275
This work has investigated the characteristics of the energy deposition throughout the spherical volume of tissue as a result of being bombarded with neutron beams of varying energies, all the way from 0.3 MeV down to thermal. Absorbed dose and dose equivalent values have been obtained throughout the spherical phantom having the ICRU-prescribed 4-element tissue composition. The basic studies involved broad, parallel beams; but the data were easily used to provide information on isotropic beam conditions also. Average dose values were easily determined. Except for the thermal neutron source case, all the beams studied were monoenergetic in character. The thermal neutron source had a Maxwellian distribution appropriate for room temperature (20/sup 0/C). The analyses were done by Monte Carlo on the CYBER 175 computer of the University of Illinois. Cross sections used were those in the latest ENDF/B files of Brookhaven National Laboratory. Point cross-sectional data were used except for the energy groups with group-averaged values for the cross sections. This work was supported by a grant from the US National Science Foundation.
- OSTI ID:
- 6044275
- Country of Publication:
- United States
- Language:
- English
Similar Records
Calculation of low-energy neutron dose indices and depth doses in the ICRU tissue sphere
Assessment of quantities for radiation protection in the ICRU standard tissue sphere for intermediate energy neutrons
Effects of cross-section structure on the dosimetric response functions for 0. 4 to 10. 0 MeV neutrons in the ICRU tissue sphere
Journal Article
·
Mon Feb 28 23:00:00 EST 1983
· Radiat. Res.; (United States)
·
OSTI ID:5502077
Assessment of quantities for radiation protection in the ICRU standard tissue sphere for intermediate energy neutrons
Thesis/Dissertation
·
Mon Dec 31 23:00:00 EST 1984
·
OSTI ID:5924125
Effects of cross-section structure on the dosimetric response functions for 0. 4 to 10. 0 MeV neutrons in the ICRU tissue sphere
Journal Article
·
Fri Aug 01 00:00:00 EDT 1986
· Radiat. Res.; (United States)
·
OSTI ID:7259808
Related Subjects
61 RADIATION PROTECTION AND DOSIMETRY
655003* -- Medical Physics-- Dosimetry
BARYONS
DATA
DOSE EQUIVALENTS
DOSES
DOSIMETRY
ELEMENTARY PARTICLES
EXPERIMENTAL DATA
FERMIONS
HADRONS
ICRU
INFORMATION
INTERNATIONAL ORGANIZATIONS
MATERIALS
MOCKUP
MONTE CARLO METHOD
NEUTRON DOSIMETRY
NEUTRONS
NUCLEONS
NUMERICAL DATA
PHANTOMS
RADIATION DOSES
SLOW NEUTRONS
STRUCTURAL MODELS
TISSUE-EQUIVALENT MATERIALS
655003* -- Medical Physics-- Dosimetry
BARYONS
DATA
DOSE EQUIVALENTS
DOSES
DOSIMETRY
ELEMENTARY PARTICLES
EXPERIMENTAL DATA
FERMIONS
HADRONS
ICRU
INFORMATION
INTERNATIONAL ORGANIZATIONS
MATERIALS
MOCKUP
MONTE CARLO METHOD
NEUTRON DOSIMETRY
NEUTRONS
NUCLEONS
NUMERICAL DATA
PHANTOMS
RADIATION DOSES
SLOW NEUTRONS
STRUCTURAL MODELS
TISSUE-EQUIVALENT MATERIALS