Magnetic measurements on insertion devices at NSLS

Journal Article · · Rev. Sci. Instrum.; (United States)
DOI:https://doi.org/10.1063/1.1140919· OSTI ID:6042092
Magnetic measurements on three insertion devices for use in the National Synchrotron Light Source (NSLS) x-ray ring are described. Hall probes were used for field mapping, and rotating long coils were used to determine integrated multipole coefficients. Results are presented for an iron pole-REC hybrid indulator, a vanadium permendur pole-REC hybrid wiggler, and a 5 T superconducting wiggler.
Research Organization:
National Synchrotron Light Source, Brookhaven National Observatory, Upton, New York 11973 (US); Hitachi Research Laboratory, Hitachi Ltd., 1-1, Saiwaicho 3 chome, Hitachi-shi, Ibaraki-ken, 317 Japan