Title: Loyola University, New Orleans, Louisiana solar energy system performance evaluation, February 1981-June 1981

Technical Report ·
DOI:https://doi.org/10.2172/6036793· OSTI ID:6036793

The Loyola University site is a student dormitory in New Orleans, Louisiana whose active solar energy system is designed to supply 52% of the hot water demand. The system is equipped with 4590 square feet of flat-plate collectors, a 5000-gallon water tank, auxiliary water supplied at high temperature and pressure from a central heating plant with a gas-fired boiler, and a differential controller that selects from 5 operating modes. System performance data are given, including the solar fraction, solar savings ratio, conventional fuel savings, system performance factor, and system coefficient of performance. The solar fraction is well below the design goal; this is attributed to great fluctuations in demand. Insolation, temperature, operation and solar energy utilization data are also presented. The performance of the collector, storage, and domestic hot water subsystems, the system operating energy, energy savings, and weather conditions are also evaluated. Appended are a system description, performance evaluation techniques and equations, site history, sensor technology, and typical monthly data. (LEW)

Research Organization:
Automation Industries, Inc., Silver Spring, MD (USA). Vitro Labs. Div.
DOE Contract Number:
AC01-79CS30027
OSTI ID:
6036793
Report Number(s):
SOLAR/1055-81/14; ON: DE82003357
Country of Publication:
United States
Language:
English