NCG turbocompressor development program
Conference
·
OSTI ID:603411
Barber-Nichols, Pacific Gas and Electric and UNOCAL as an industry group applied for a DOE grant under the GTO to develop a new type of compressor that could be used to extract non-condensable gas (NCG) from the condensers of geothermal power plants. This grant (DE-FG07-951A13391) was awarded on September 20, 1995. The installation and startup of the turbocompressor at the PG&E Geysers Unit 11 is covered by this paper. The turbocompressor has operated several days at 17000rpm while the plant was producing 50 to 70 MW.