Barber-Nichols, Pacific Gas and Electric and UNOCAL as an industry group applied for a DOE grant under the GTO to develop a new type of compressor that could be used to extract non-condensable gas (NCG) from the condensers of geothermal power plants. This grant (DE-FG07-951A13391) was awarded on September 20, 1995. The installation and startup of the turbocompressor at the PG&E Geysers Unit 11 is covered by this paper. The turbocompressor has operated several days at 17000rpm while the plant was producing 50 to 70 MW.
Research Organization:
USDOE Assistant Secretary for Energy Efficiency and Renewable Energy, Washington, DC (United States)
OSTI ID:
603411
Report Number(s):
DOE/EE--0139; CONF-970376--; ON: DE98001891
Country of Publication:
United States
Language:
English

Similar Records

High performance turbocompressor for non-condensable gas removal at geothermal power plants
Conference · Wed Jul 01 00:00:00 EDT 1998 · OSTI ID:20002767

Development of turbine driven centrifugal compressors for non-condensible gas removal at geothermal power plants. Final report
Technical Report · Mon Dec 15 23:00:00 EST 1997 · OSTI ID:570103

Private development of geothermal power plants at The Geysers
Journal Article · · Bull., Geotherm. Resour. Counc. (Davis, Calif.); (United States) · OSTI ID:6210134