Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Chemical-cleaning process evaluation: Westinghouse steam generators. Final report. [PWR]

Technical Report ·
OSTI ID:6026803
The Steam Generator Owners Group (SGOG)/Electric Power Research Institute (EPRI) Steam Generator Secondary Side Chemical Cleaning Program, under develpment since 1978, has resulted in a generic process for the removal of accumulated corrosion products and tube deposits in the tube support plate crevices. The SGOG/EPRI Project S150-3 was established to obtain an evaluation of the generic process in regard to its applicability to Westinghouse steam generators. The results of the evaluation form the basis for recommendations for transferring the generic process to a plant specific application and identify chemical cleaning corrosion guidelines for the materials in Westinghouse Steam Generators. The results of the evaluation, recommendations for plant-specific applications and corrosion guidelines for chemical cleaning are presented in this report.
Research Organization:
Westinghouse Electric Corp., Pittsburgh, PA (USA). Nuclear Technology Div.
OSTI ID:
6026803
Report Number(s):
EPRI-NP-2987; ON: DE83902286
Country of Publication:
United States
Language:
English