Emergency pipe line repair connects subsea pipe lines
Journal Article
·
· Pipe Line Industry; (USA)
OSTI ID:6025093
- Elf Aquitaine Research Center, Pau (FR)
- British Gas plc, Newcastle upon Tyne (UK). Engineering Research Station
Torque testing to check the integrity of the Titus subsea connector and flare testing of 36-in. pipe to determine pipe strain are discussed. The authors also present their conclusions on the overall test program.
- OSTI ID:
- 6025093
- Journal Information:
- Pipe Line Industry; (USA), Journal Name: Pipe Line Industry; (USA) Vol. 73:6; ISSN 0032-0145; ISSN PLINA
- Country of Publication:
- United States
- Language:
- English
Similar Records
Emergency pipe line repair connects subsea pipe lines
Rotating connection assembly for subsea pipe connection
Diverless pipeline-repair system passes tests for 20-in. pipe
Journal Article
·
Wed Oct 31 23:00:00 EST 1990
· Pipe Line Industry; (USA)
·
OSTI ID:5888705
Rotating connection assembly for subsea pipe connection
Patent
·
Tue Sep 22 00:00:00 EDT 1987
·
OSTI ID:5950563
Diverless pipeline-repair system passes tests for 20-in. pipe
Journal Article
·
Mon May 21 00:00:00 EDT 1990
· Oil and Gas Journal; (USA)
·
OSTI ID:6744322