Post-test thermal calculations and data analyses for the Spent Fuel Test, Climax
After the Spent Fuel Test - Climax (SFT-C) was completed, additional calculations were performed using the best available (directly measured or inferred from measurements made during the test) input parameters, thermal properties, and power levels. This report documents those calculations and compares the results with measurements made during the three-year heating phase and six-month posttest cooling phase of the SFT-C. Three basic types of heat-transfer calculations include a combined two-dimensional/three-dimensional, infinite-length, finite-difference model; a fully three-dimensional, finite-length, finite-difference model; and a fully three-dimensional, finite-length, analytical solution. The finite-length model much more accurately reflects heat flow near the ends of the array and produces cooler temperatures everywhere than does its infinite-length counterpart. 14 refs., 144 figs., 4 tabs.
- Research Organization:
- Lawrence Livermore National Lab., CA (United States)
- DOE Contract Number:
- W-7405-ENG-48
- OSTI ID:
- 60114
- Report Number(s):
- UCRL--53728; ON: DE87013822
- Country of Publication:
- United States
- Language:
- English