Pollutant emission rates from a radiant fiber-matrix unvented gas space heater
A prototype unvented gas space heater (UVGSH) using a radiant fiber-matrix burner was operated in a 27 m/sup 3/ (950 ft/sup 3/) environmental chamber under two firing rates and at two different excess-air settings. Pollutant emission rates for carbon monoxide (CO), nitric oxide (NO), and nitrogen dioxide (NO/sub 2/) are reported. When compared to previously tested UVGSH's the radiant fiber-matrix burner was found to emit less CO and NO/sub 2/ per unit of fuel consumed. 5 refs., 2 figs., 1 tab.
- Research Organization:
- Lawrence Berkeley Lab., CA (USA)
- DOE Contract Number:
- AC03-76SF00098
- OSTI ID:
- 6007026
- Report Number(s):
- LBL-26306; ON: DE89013411
- Country of Publication:
- United States
- Language:
- English
Similar Records
Comparison of pollutant emission rates from unvented kerosene and gas space heaters
Pollutant emission rates from a radiant fiber-matrix gas burner
Pollutant emission rates from unvented infrared and convective gas-fired space heaters
Conference
·
Thu May 01 00:00:00 EDT 1986
·
OSTI ID:5256378
Pollutant emission rates from a radiant fiber-matrix gas burner
Journal Article
·
Sun Jan 31 23:00:00 EST 1993
· Air and Waste; (United States)
·
OSTI ID:6314452
Pollutant emission rates from unvented infrared and convective gas-fired space heaters
Technical Report
·
Wed Feb 29 23:00:00 EST 1984
·
OSTI ID:5711555
Related Subjects
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION
320106* -- Energy Conservation
Consumption
& Utilization-- Building Equipment-- (1987-)
320107 -- Energy Conservation
Consumption
& Utilization-- Building Systems-- (1987-)
AIR POLLUTION
AIR QUALITY
APPLIANCES
BUILDINGS
BURNERS
CARBON COMPOUNDS
CARBON MONOXIDE
CARBON OXIDES
CHALCOGENIDES
COMBUSTION PROPERTIES
ENVIRONMENTAL QUALITY
GAS BURNERS
HEATERS
HOUSES
NITRIC OXIDE
NITROGEN COMPOUNDS
NITROGEN DIOXIDE
NITROGEN OXIDES
OXIDES
OXYGEN COMPOUNDS
POLLUTION
RESIDENTIAL BUILDINGS
SPACE HEATERS
320106* -- Energy Conservation
Consumption
& Utilization-- Building Equipment-- (1987-)
320107 -- Energy Conservation
Consumption
& Utilization-- Building Systems-- (1987-)
AIR POLLUTION
AIR QUALITY
APPLIANCES
BUILDINGS
BURNERS
CARBON COMPOUNDS
CARBON MONOXIDE
CARBON OXIDES
CHALCOGENIDES
COMBUSTION PROPERTIES
ENVIRONMENTAL QUALITY
GAS BURNERS
HEATERS
HOUSES
NITRIC OXIDE
NITROGEN COMPOUNDS
NITROGEN DIOXIDE
NITROGEN OXIDES
OXIDES
OXYGEN COMPOUNDS
POLLUTION
RESIDENTIAL BUILDINGS
SPACE HEATERS