Ground-coupled heat-pump-system experimental results
Conference
·
OSTI ID:5997987
Since October 1980, a small house in Upton, Long Island, New York has been heated and cooled by a liquid source heat pump using a shallow serpentine earth coil as a heat source/sink. After a brief introduction and system description, system performance data are presented, for the winter of 1981-82 and the summer of 1982, followed by a discussion of these results. The experimental test house is a 104 m/sup 2/ (1120 ft/sup 2/) 3-bedroom ranch of energy-saving construction with a heating load of 7.8 x 10/sup 6/ J//sup 0/C-day (4.1 x 10/sup 3/ Btu//sup 0/F-day). The heat pump used during most of the period reported on here is a commercially available water-to-air unit sized to just meet the building design heating load with no auxiliary heat. The earth coil contains 155 m (507 ft) of nominal 1-1/2 in. medium density polyethylene pipe, and is buried 1.2 m (4 ft) deep. An antifreeze solution, consisting of approximately 25% ethylene glycol in water, is employed to permit subfreezing earth coil operation. Two independent data acquisition systems, a datalogger-microcomputer system backed up by a Btu-meter, monitor the space conditioning system performance. During the winter of 1981-82, the system, which extracted 15.5 x 10/sup 9/ J (14.7 x 10/sup 6/ Btu) of heat from the ground, operated with a seasonal performance factor (SPF) of 2.46. No resistance heating was used. The minimum earth coil daily U-value observed during this season was 3.34 W/m/sup 0/C (1.93 Btu/ft-hr-/sup 0/F). During the summer of 1982, a total of 10.6 x 10/sup 9/ J (10.0 x 10/sup 6/ Btu) of heat was rejected to the ground. The system SPF was 1.91, with a minimum daily U-value of 3.53 W/m/sup 0/C (2.04 Btu/ft-hr-/sup 0/F).
- Research Organization:
- Brookhaven National Lab., Upton, NY (USA)
- DOE Contract Number:
- W-7405-ENG-26
- OSTI ID:
- 5997987
- Report Number(s):
- CONF-830640-6; ON: DE83014011
- Country of Publication:
- United States
- Language:
- English
Similar Records
Ground-coupled heat pump system experimental results
Design, operation and performance of a ground coupled heat pump system in a cold climate
TECH House I horizontal coil ground coupled heat pump: 1982-1983 heating season performance
Conference
·
Wed Jun 01 00:00:00 EDT 1983
· ASHRAE Trans.; (United States)
·
OSTI ID:6772338
Design, operation and performance of a ground coupled heat pump system in a cold climate
Conference
·
Wed Dec 31 23:00:00 EST 1980
·
OSTI ID:6471711
TECH House I horizontal coil ground coupled heat pump: 1982-1983 heating season performance
Technical Report
·
Tue Jan 31 23:00:00 EST 1984
·
OSTI ID:5279292
Related Subjects
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION
320101* -- Energy Conservation
Consumption
& Utilization-- Residential Buildings-- (-1987)
BUILDINGS
DATA ACQUISITION
FEDERAL REGION II
GROUND SOURCE HEAT PUMPS
HEAT EXTRACTION
HEAT PUMPS
HOUSES
NEW YORK
NORTH AMERICA
PERFORMANCE
PIPES
RESIDENTIAL BUILDINGS
USA
WATER SOURCE HEAT PUMPS
320101* -- Energy Conservation
Consumption
& Utilization-- Residential Buildings-- (-1987)
BUILDINGS
DATA ACQUISITION
FEDERAL REGION II
GROUND SOURCE HEAT PUMPS
HEAT EXTRACTION
HEAT PUMPS
HOUSES
NEW YORK
NORTH AMERICA
PERFORMANCE
PIPES
RESIDENTIAL BUILDINGS
USA
WATER SOURCE HEAT PUMPS