Beat-to-beat left ventricular performance in atrial fibrillation: radionuclide assessment with the computerized nuclear probe
Journal Article
·
· Am. J. Cardiol.; (United States)
There is wide beat-to-beat variability in cycle length and left ventricular performance in patients with atrial fibrillation. In this study, left ventricular ejection fraction and relative left ventricular volumes were evaluated on a beat-to-beat basis with the computerized nuclear probe, an instrument with sufficiently high sensitivity to allow continuous evaluation of the radionuclide time-activity curve. Of 18 patients with atrial fibrillation, 5 had mitral stenosis, 6 had mitral regurgitation, and 7 had coronary artery disease. Fifty consecutive beats were analyzed in each patient. The mean left ventricular ejection fraction ranged from 17 to 51%. There was substantial beat-to-beat variation in cycle length and left ventricular ejection fraction in all patients, including those with marked left ventricular dysfunction. In 14 patients who also underwent multiple gated cardiac blood pool imaging, there was an excellent correlation between mean ejection fraction derived from the nuclear probe and gated ejection fraction obtained by gamma camera imaging (r . 0.90). Based on beat-to-beat analysis, left ventricular function was dependent on relative end-diastolic volume and multiple preceding cycle lengths, but not preceding end-systolic volumes. This study demonstrates that a single value for left ventricular ejection fraction does not adequately characterize left ventricular function in patients with atrial fibrillation. Furthermore, both the mean beat-to-beat and the gated ejection fraction may underestimate left ventricular performance at rest in such patients.
- Research Organization:
- Nuclear Medicine Section, Yale University School of Medicine, New Haven, Connecticut
- OSTI ID:
- 5979791
- Journal Information:
- Am. J. Cardiol.; (United States), Journal Name: Am. J. Cardiol.; (United States) Vol. 51:7; ISSN AJCDA
- Country of Publication:
- United States
- Language:
- English
Similar Records
Effect of increasing heart rate in patients with aortic regurgitation. Effect of incremental atrial pacing on scintigraphic, hemodynamic and thermodilution measurements
Measurement of ventricular function by ECG gating during atrial fibrillation
Influence of heart rate and atrial transport on left ventricular volume and function: relation to hemodynamic changes produced by supraventricular arrhythmia
Journal Article
·
Tue Jun 01 00:00:00 EDT 1982
· Am. J. Cardiol.; (United States)
·
OSTI ID:7055933
Measurement of ventricular function by ECG gating during atrial fibrillation
Journal Article
·
Sat Feb 28 23:00:00 EST 1981
· J. Nucl. Med.; (United States)
·
OSTI ID:6823187
Influence of heart rate and atrial transport on left ventricular volume and function: relation to hemodynamic changes produced by supraventricular arrhythmia
Journal Article
·
Thu Oct 01 00:00:00 EDT 1981
· Am. J. Cardiol.; (United States)
·
OSTI ID:5584348
Related Subjects
550601* -- Medicine-- Unsealed Radionuclides in Diagnostics
551001 -- Physiological Systems-- Tracer Techniques
59 BASIC BIOLOGICAL SCIENCES
62 RADIOLOGY AND NUCLEAR MEDICINE
BODY
CARDIOVASCULAR SYSTEM
COMPUTER CALCULATIONS
DIAGNOSTIC TECHNIQUES
DYNAMIC FUNCTION STUDIES
ELEMENTS
HEART
ISOTOPE APPLICATIONS
METALS
ORGANS
PATIENTS
TECHNETIUM
TRACER TECHNIQUES
TRANSITION ELEMENTS
551001 -- Physiological Systems-- Tracer Techniques
59 BASIC BIOLOGICAL SCIENCES
62 RADIOLOGY AND NUCLEAR MEDICINE
BODY
CARDIOVASCULAR SYSTEM
COMPUTER CALCULATIONS
DIAGNOSTIC TECHNIQUES
DYNAMIC FUNCTION STUDIES
ELEMENTS
HEART
ISOTOPE APPLICATIONS
METALS
ORGANS
PATIENTS
TECHNETIUM
TRACER TECHNIQUES
TRANSITION ELEMENTS