Gas-turbine topping-cycle industrial-cogeneration system. Annual report, January-December 1984

Technical Report ·
OSTI ID:5976992

A gas-turbine topping-cycle cogeneration system is being developed to specifically meet the needs of industrial cogenerators in the 2-10 MWe range. Emphasis is placed on system integration. A single, prime reliable drive train and a single control center replace a wide assortment of nonintegrated, free-standing power drives and control centers. The system produces a nominal 3 MWe of power and 19,500 lb/hr of 250 psig saturated steam using an Allison 501-KH gas turbine and a natural-circulation waste heat boiler. A steam-injected feature is employed to increase output to 4 MWe when process-steam demand diminishes. The system is prepackaged, skid-mounted and delivered in four modules; one each for the machinery, duct burner, waste heat boiler and controls.

Research Organization:
Mechanical Technology, Inc., Latham, NY (USA)
OSTI ID:
5976992
Report Number(s):
PB-86-103850/XAB; MTI-85TR45
Country of Publication:
United States
Language:
English