Spent fuel dry storage technology development: fuel temperature measurements under imposed dry storage conditions (I kW PWR spent fuel assembly)
A spent fuel assembly temperature test under imposed dry storage conditions was conducted at the Engine Maintenance Assembly and Disassembly (E-MAD) facility on the Nevada Test Site in support of spent fuel dry storage technology development. This document presents the test data and results obtained from an approximately 1.0 kW decay heat level PWR spent fuel assembly. A spent fuel test apparatus was designed to utilize a representative stainless steel spent fuel canister, a canister lid containing internal temperature instrumentation to measure fuel cladding temperatures, and a carbon steel liner that encloses the canister and lid. Electrical heaters along the liner length, on the lid, and below the canister are used to impose dry storage canister temperature profiles. Temperature instrumentation is provided on the liner and canister. The liner and canister are supported by a test stand in one of the large hot cells (West Process Cell) inside E-MAD. Fuel temperature measurements have been performed using imposed canister temperature profiles from the electrically heated and spent fuel drywell tests being conducted at E-MAD as well as for four constant canister temperature profiles, each with a vacuum, helium and air backfill. Computer models have been utilized in conjunction with the test to predict the thermal response of the fuel cladding. Computer predictions are presented, and they show good agreement with the test data.
- Research Organization:
- Westinghouse Electric Corp., Pittsburgh, PA (United States). Advanced Energy Systems Div.
- DOE Contract Number:
- AC08-76NV00597
- OSTI ID:
- 59725
- Report Number(s):
- DOE/NV/00597-4; TRN: 81:009113
- Resource Relation:
- Other Information: PBD: Sep 1980
- Country of Publication:
- United States
- Language:
- English
Similar Records
Spent fuel dry storage technology development: thermal evaluation of isolated drywells containing spent fuel (1 kW PWR spent fuel assembly)
Spent fuel dry storage technology development: thermal evaluation of three adjacent drywells (each containing a 0.6 kW PWR spent fuel assembly)