Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Filter and slice thickness selection in SPECT image reconstruction

Conference · · J. Nucl. Med.; (United States)
OSTI ID:5971251
The choice of filter and slice thickness in SPECT image reconstruction as function of activity and linear and angular sampling were investigated in phantom and patient imaging studies. Reconstructed transverse and longitudinal spatial resolution of the system were measured using a line source in a water filled phantom. Phantom studies included measurements of the Data Spectrum phantom; clinical studies included tomographic procedures in 40 patients undergoing imaging of the temporomandibular joint. Slices of the phantom and patient images were evaluated for spatial of the phantom and patient images were evaluated for spatial resolution, noise, and image quality. Major findings include; spatial resolution and image quality improve with increasing linear sampling frequencies over the range of 4-8 mm/p in the phantom images, best spatial resolution and image quality in clinical images were observed at a linear sampling frequency of 6mm/p, Shepp and Logan filter gives the best spatial resolution for phantom studies at the lowest linear sampling frequency; smoothed Shepp and Logan filter provides best quality images without loss of resolution at higher frequencies and, spatial resolution and image quality improve with increased angular sampling frequency in the phantom at 40 c/p but appear to be independent of angular sampling frequency at 400 c/p.
Research Organization:
Univ. of Rochester School of Medicine and Dentistry, Rochester, NY
OSTI ID:
5971251
Report Number(s):
CONF-850611-
Conference Information:
Journal Name: J. Nucl. Med.; (United States) Journal Volume: 26:5
Country of Publication:
United States
Language:
English

Similar Records

Implementation of linear filters for iterative penalized maximum likelihood SPECT reconstruction
Journal Article · Sun Mar 31 23:00:00 EST 1991 · IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (United States) · OSTI ID:5012813

The design and clinical utilities of a fan beam collimator for a SPECT system
Conference · Sat Dec 31 23:00:00 EST 1983 · J. Nucl. Med.; (United States) · OSTI ID:6591050

Development of the new phantom for evaluation of SPECT performance
Conference · Sat Dec 31 23:00:00 EST 1983 · J. Nucl. Med.; (United States) · OSTI ID:6843561