Seismic damping factors of small-bore piping as influenced by insulation and support elements

Conference ·
OSTI ID:5969514
Seismic damping tests of a prototypical Liquid Metal Fast Breeder Reactor (LMFBR) small-bore piping system is described, and measured transient responses to pulse excitations are reported. The test specimen was representative of a typical LMFBR insulated small-bore piping system, and it was supported from a rigid test fame by prototypic dead-weight supports, mechanical snubbers, and pipe clamps. Various support configurations were tested to assess the reponse sensitivity to insulation and use of mechanical snubbers. Factors much higher than the magnitudes currently allowed in design, by the USNRC Regulatory Guide 1.61, were found. This verified the design values but also pointed out the possibility of undue conservatism and costly overdesign resulting from use of the present design values.
Research Organization:
Westinghouse Hanford Co., Richland, WA (USA)
DOE Contract Number:
AC06-76FF02170
OSTI ID:
5969514
Report Number(s):
HEDL-SA-2845-FP; CONF-830607-21; ON: DE83015475
Country of Publication:
United States
Language:
English

Similar Records

Seismic damping factors of small bore piping as influenced by insulation and support elements
Conference · Fri Dec 31 23:00:00 EST 1982 · Am. Soc. Mech. Eng., Pressure Vessels Piping Div., (Tech. Rep.) PVP; (United States) · OSTI ID:5453916

Seismic damping factors of small bore piping as influenced by insulation and support elements
Journal Article · Wed May 01 00:00:00 EDT 1985 · J. Pressure Vessel Technol.; (United States) · OSTI ID:6310147

Seismic response and damping tests of small bore LMFBR piping and supports
Conference · Sat Dec 31 23:00:00 EST 1983 · OSTI ID:6977138