Title: Measurement of neutral beam species ratio by solid-state detector

Journal Article · · Rev. Sci. Instrum.; (United States)
DOI:https://doi.org/10.1063/1.1138279· OSTI ID:5965515

Energy spectra of neutral hydrogen beams produced at the prototype JT-60 neutral beam injector unit were measured by the solid-state detector which was developed for a neutral particle analyzer for fusion devices. The ion beam species ratio estimated from the energy spectra agreed well with that measured by the Doppler-shift spectrometer.

Research Organization:
Japan Atomic Energy Research Institute, 801-1 Mukohyama, Naka-machi, Naka-gun, Ibaraki-ken, 311-02, Japan