Test results for a Stirling-engine-driven heat-actuated heat pump breadboard system

Conference · · Proc., Intersoc. Energy Convers. Eng. Conf.; (United States)
OSTI ID:5959953

A Free-Piston Stirling Engine prime mover has been coupled to a Rankine-cycle, linearresonant refrigerant compressor through a diaphragm-actuated hydraulic coupling. The system, developed at Mechanical Technology Incorporated, is a heat-actuated heat pump (HAHP) that was developed for residential applications. This paper describes the breadboard system, and presents the data obtained during testing the past year. The system was successfully tested at four designated operating points in over 250 hours of operating time, during which time extensive data was recorded that characterizes the system's performance/ operation over the specified operating range, and defines the future product potential.

Research Organization:
Mechanical Technology Incorporated, Latham, New York
OSTI ID:
5959953
Report Number(s):
CONF-840804-
Journal Information:
Proc., Intersoc. Energy Convers. Eng. Conf.; (United States), Journal Name: Proc., Intersoc. Energy Convers. Eng. Conf.; (United States) Vol. 3; ISSN PIECD
Country of Publication:
United States
Language:
English