Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

A comparison of methods for calculating audible noise of high voltage transmission lines

Journal Article · · IEEE Trans. Power Appar. Syst.; (United States)
OSTI ID:5957112
During the last several years, audible noise produced by high voltage transmission lines in corona has emerged as an important design consideration. In this same time frame a number of different methods for calculating audible noise levels have been proposed. The methods currently available, for both ac and dc lines, are described in this paper and are compared through application to practical line geometries for which data from long-term measurements are available.
Research Organization:
General Electric Co.
OSTI ID:
5957112
Journal Information:
IEEE Trans. Power Appar. Syst.; (United States), Journal Name: IEEE Trans. Power Appar. Syst.; (United States) Vol. PAS-101:10; ISSN IEPSA
Country of Publication:
United States
Language:
English