In-line x-ray fluorescence analysis of special nuclear materials in dissolver solution: laboratory development and simulation studies
Technical Report
·
OSTI ID:5955524
An automated x-ray fluorescence analysis apparatus and sampling system has been designed for a proof-of-principle test of on-line x-ray fluorescence assay of special nuclear materials in dissolver solutions. A sampling technique is described in which the sample may be a large aliquot or an entire, ''totally sampled'' batch of solutions. The total sample technique used with an internal standard gives total mass assays with no need for a tank volume measurement, thereby eliminating errors of aliquotting and tank volume measurement. The test XRF apparatus has been used for the generation of a data base consisting of the usable concentration ranges and times required for attaining targeted standard deviations for assays of dilute plutonium dissolved in high-density uranium solutions, using the uranium-thorium pair as surrogate for plutonium-uranium. Error propagation equations have been derived for governing the efficient accumulation of high-precision data under the extremely low signal-to-noise conditions encountered with dilute SNM in dense matrices. The data base, used as input to the error propagation equations, is used for specifying the parameters of x-ray fluorescence analysis equipment that will meet any targeted assaying precision and assay time requirements. Assay accuracy at low levels of analyst is critically dependent on the accuracy of the background determination. A data-taking strategy which uses a short dwell time at each spectrometer setting is effective in compensating for long-term instrumental drift. The effects on assay time and precision of the reflecting power and diffraction halfwidth of the analyzing crystal, spectrometer design, signal-to-noise ratios, x-ray detection system, and exciting x-ray power are discussed. 8 refs.
- Research Organization:
- Monsanto Research Corp., Miamisburg, OH (USA). Mound
- DOE Contract Number:
- AC04-76DP00053
- OSTI ID:
- 5955524
- Report Number(s):
- MLM-3335; ON: DE86007990
- Country of Publication:
- United States
- Language:
- English
Similar Records
In-line x-ray fluorescence analysis of special nuclear materials in dissolver solution: materials development, laboratory simulation and parameterization
Sampling and data-taking strategies in x-ray fluorescence assay of low S/N solutions
In-line X-ray fluorescence analysis of special nuclear materials in dissolver solution: Materials development, laboratory simulation and parameterization
Conference
·
Mon Dec 31 23:00:00 EST 1984
·
OSTI ID:5445381
Sampling and data-taking strategies in x-ray fluorescence assay of low S/N solutions
Conference
·
Mon Dec 31 23:00:00 EST 1984
·
OSTI ID:5281500
In-line X-ray fluorescence analysis of special nuclear materials in dissolver solution: Materials development, laboratory simulation and parameterization
Conference
·
Mon Dec 31 23:00:00 EST 1984
· J. Nucl. Mater. Manage.; (United States)
·
OSTI ID:5399593
Related Subjects
055001 -- Nuclear Fuels-- Safeguards
Inspection
& Accountability-- Technical Aspects
37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CHEMISTRY
400101* -- Activation
Nuclear Reaction
Radiometric & Radiochemical Procedures
98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL PROTECTION
ACTINIDES
CHEMICAL ANALYSIS
DISPERSIONS
DISSOLVERS
ELEMENTS
METALS
MIXTURES
NONDESTRUCTIVE ANALYSIS
ON-LINE MEASUREMENT SYSTEMS
ON-LINE SYSTEMS
PLUTONIUM
PROCESS SOLUTIONS
QUANTITATIVE CHEMICAL ANALYSIS
SOLUTIONS
TRANSURANIUM ELEMENTS
URANIUM
X-RAY EMISSION ANALYSIS
X-RAY FLUORESCENCE ANALYSIS
Inspection
& Accountability-- Technical Aspects
37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CHEMISTRY
400101* -- Activation
Nuclear Reaction
Radiometric & Radiochemical Procedures
98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL PROTECTION
ACTINIDES
CHEMICAL ANALYSIS
DISPERSIONS
DISSOLVERS
ELEMENTS
METALS
MIXTURES
NONDESTRUCTIVE ANALYSIS
ON-LINE MEASUREMENT SYSTEMS
ON-LINE SYSTEMS
PLUTONIUM
PROCESS SOLUTIONS
QUANTITATIVE CHEMICAL ANALYSIS
SOLUTIONS
TRANSURANIUM ELEMENTS
URANIUM
X-RAY EMISSION ANALYSIS
X-RAY FLUORESCENCE ANALYSIS