Progress report on construction and testing of a 3 MEV, DC, ampere intensity electron beam recirculation system

Conference · · IEEE Trans. Nucl. Sci.; (United States)
OSTI ID:5948440
Construction is underway on a 3 MV electrostatic accelerator designed to recirculate D.C. electron beams with intensities up to 4 amperes. The test facility includes a 3 MV, SF/sub 6/ insulated vertical accelerator with parallel accelerator and decelerator tubes, diagnostic equipment, and vacuum and beam line components to bend the beam 180/sup 0/ and return it to the terminal. Special consideration has been given to cathode, electron gun, electron collector, and optical design to allow beam recovery efficiency of better than 99.99% at currents up to 4 amperes.
Research Organization:
National Electrostatics Corporation, Middleton, WI
OSTI ID:
5948440
Report Number(s):
CONF-850504-
Conference Information:
Journal Name: IEEE Trans. Nucl. Sci.; (United States) Journal Volume: NS-32:5
Country of Publication:
United States
Language:
English