Heterodyne measurements of electron cyclotron emission from Alcator A and absolute submillimeter receiver calibration
Electron cyclotron emission (ECE) from thermal plasmas in the Alcator A tokamak for harmonics from 2nd through 5th and up to the 7th harmonic for nonthermal plasmas have been observed in the frequency range of 400--800 GHz using a sensitive, low-noise submillimeter heterodyne receiver. The sensitivity of the receiver (approx.10/sup -20/ W Hz/sup -1/) allowed for the measurement of 4th and 5th harmonic ECE from thermal plasmas with T/sub e/roughly-equal800 eV. The receiver was absolutely calibrated and its field of view was experimentally determined. A careful analysis has been made to relate the receiver calibration to the plasma-emitting volume, taking into account radiation coherence time, wall reflections, polarization scrambling, window losses, and aperture restrictions.
- Research Organization:
- Plasma Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139
- OSTI ID:
- 5938903
- Journal Information:
- J. Appl. Phys.; (United States), Vol. 52:12
- Country of Publication:
- United States
- Language:
- English
Similar Records
Heterodyne receiver for the submillimeter wavelength region based on cyclotron resonance in InSb at low temperatures
Electron cyclotron measurements with the fast-scanning heterodyne radiometer on the tokamak fusion test reactor
Related Subjects
ALCATOR DEVICE
ELECTRON CYCLOTRON-RESONANCE
HETERODYNE RECEIVERS
CALIBRATION
CYCLOTRON RADIATION
GHZ RANGE
HARMONICS
PLASMA
SENSITIVITY
TOKAMAK DEVICES
BREMSSTRAHLUNG
CLOSED PLASMA DEVICES
CYCLOTRON RESONANCE
ELECTROMAGNETIC RADIATION
ELECTRONIC EQUIPMENT
EQUIPMENT
FREQUENCY RANGE
MICROWAVE EQUIPMENT
OSCILLATIONS
RADIATIONS
RADIO EQUIPMENT
RESONANCE
THERMONUCLEAR DEVICES
700101* - Fusion Energy- Plasma Research- Confinement
Heating
& Production