Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

National Dioxin Study Tier 4 - combustion sources: final test report - Site 6, wire reclamation incinerator WRI-A

Technical Report ·
OSTI ID:5936213
This report summarizes the results of a dioxin/furan emissions test of a wire-reclamation incinerator equipped with an afterburner for hydrocarbon emissions control. The wire reclamation incinerator is used for recovery of copper from coated copper wire and drained transformer cores. The test was the sixth in a series of several dioxin/furan emissions tests conducted under Tier 4 of the National Dioxin Study. The primary objective of Tier 4 is to determine if various combustion sources are sources of dioxin and/or furan emissions. If any of the combustion sources are found to emit dioxin or furan, the secondary objective of Tier 4 is to quantify these emissions. Wire reclamation incinerators are one of 8 combustion-source categories that have been tested in the Tier 4 program. The tested incinerator WRI-A was selected for the test after an initial information screening and a one-day pretest survey visit. Incinerator WRI-A is considered representative of the wire-reclamation incinerator population in the United States. Data presented in the report include dioxin (tetra through octa homologue + 2378 TCDD) and furan (tetra through octa homologue + 2378 TCDF) results for both stack samples and ash samples. In addition, process data collected during sampling are also presented.
Research Organization:
Radian Corp., Research Triangle Park, NC (USA)
OSTI ID:
5936213
Report Number(s):
PB-88-101142/XAB; RAD-87-222-109-02-22
Country of Publication:
United States
Language:
English