Three fracturing fluids--a crosslinked guar, a delayed hydrating guar, and a linear guar--were tested for fluid loss control at set time intervals while being conditioned in a heated, pressurized flow loop. Each fluid was tested with 3 different fluid loss additive systems: diesel, silica flour, and a combination of diesel and silica flour. The crosslinked system was tested also with 2 additional fluid loss additive systems. These fluids were diesel plus an anionic surfactant and the combination of diesel/silica flour plus the anionic surfactant. These tests show that the fluid loss of crosslinked fracturing fluids is best controlled by using diesel in combination with a surfactant or a properly sized particulate material. The fluid loss of linear fluids is controlled best with particulate additives.