Title: Experimental and calculational results from the Spent Fuel Test-Climax

Conference ·
OSTI ID:59265

The Spent Fuel Test-Climax (SFT-C) is being conducted under the technical direction of the Lawrence Livermore National Laboratory for the US Department of Energy. The SFT-C is located 420 m below surface in the Climax placed in test storage in April and May 1980. At the same time, 6 electrical elevated-temperature phase of the test. Data related to heat transfer, thermomechanical response, radiation dose, and radiation damage have been collected and are presented here, as appropriate, with calculational results. In general, measured and calculated results compare well.

Research Organization:
Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
DOE Contract Number:
W-7405-ENG-48
OSTI ID:
59265
Report Number(s):
UCRL-88254; CONF-8210101-2; ON: DE83004217
Resource Relation:
Conference: Workshop on in situ experiments in granite associated with geological disposal of radioactive waste, Stockholm (Sweden), 25-27 Oct 1982; Other Information: DN: Portions of document are illegible; PBD: 14 Oct 1982
Country of Publication:
United States
Language:
English