Determination of uranium in uranium metal, uranium oxides, and uranyl nitrate solutions by potentiometric titration

Conference ·
OSTI ID:5924813
A simple, fast method for the determination of uranium in uranium metal, uranium oxides, and uranyl nitrate solutions has been adapted from the Davies-Gray volumetric method to meet the needs of Y-12. One-gram duplicate aliquots of uranium metal or uranium oxide are dissolved in 1:1 HNO/sub 3/ and concentrated H/sub 2/SO/sub 4/ to sulfur trioxide fumes, and then diluted to 100-mL volume. Duplicate aliquots are then weighed for analysis. For uranyl nitrate samples, duplicate aliquots containing between 50 and 150 mg of U are weighed and analyzed directly. The weighed aliquot is transferred to a Berzelius beaker; 1.5 M sulfamic acid is added, followed in order by concentrated phosphoric acid, 1 M ferrous sulfate, and (after a 30-second interval) the oxidizing reagent. After a timed 3-minute waiting period, 100 mL of the 0.1% vanadyl sulfate-sulfuric acid mixture is added. The sample is then titrated past its endpoint with standard potassium dichromate, and the endpoint is determined by second derivative techniques on a mV/weight basis.
Research Organization:
Oak Ridge Y-12 Plant, TN (USA)
DOE Contract Number:
W-7405-ENG-26
OSTI ID:
5924813
Report Number(s):
Y/DK-345; CONF-830589-2; ON: DE83013565
Country of Publication:
United States
Language:
English