TMX Upgrade magnet-set geometry design
Conference
·
OSTI ID:5922929
A magnet set, consisting of 24 coils, has been designed for the TMX Upgrade. Like the coil set designed for the TMX experiment, the coils for TMX Upgrade consist of a central-cell set with a minimum-B plug set on each end. Between the central cell and each end plug, there is a flux bundle recircularizing transition set. Physics considerations require that the TMX Upgrade magnet set be almost twice as long as the TMX magnet set (14 m between the outer mirrors). The central circular coils are the only coils used from TMX. The TMX transition set of two C-coils and an octupole is replaced by a C-coil and an Ioffe coil. The TMX plug composed of a baseball coil and two C-coils is replaced by an Ioffe coil, two C-coils and two circular coils. A comparison between the TMX and TMX Upgrade magnet sets is shown.
- Research Organization:
- Lawrence Livermore National Lab., CA (USA)
- DOE Contract Number:
- W-7405-ENG-48
- OSTI ID:
- 5922929
- Report Number(s):
- UCRL-85979; CONF-811040-18; ON: DE82001793
- Country of Publication:
- United States
- Language:
- English