A magnet set, consisting of 24 coils, has been designed for the TMX Upgrade. Like the coil set designed for the TMX experiment, the coils for TMX Upgrade consist of a central-cell set with a minimum-B plug set on each end. Between the central cell and each end plug, there is a flux bundle recircularizing transition set. Physics considerations require that the TMX Upgrade magnet set be almost twice as long as the TMX magnet set (14 m between the outer mirrors). The central circular coils are the only coils used from TMX. The TMX transition set of two C-coils and an octupole is replaced by a C-coil and an Ioffe coil. The TMX plug composed of a baseball coil and two C-coils is replaced by an Ioffe coil, two C-coils and two circular coils. A comparison between the TMX and TMX Upgrade magnet sets is shown.
Research Organization:
Lawrence Livermore National Lab., CA (USA)
DOE Contract Number:
W-7405-ENG-48
OSTI ID:
5922929
Report Number(s):
UCRL-85979; CONF-811040-18; ON: DE82001793
Country of Publication:
United States
Language:
English

Similar Records

TMX-axisymmetric magnet-set-design study
Conference · Sun Oct 25 23:00:00 EST 1981 · OSTI ID:5968465

Octupole coil configuration for the Tandem Mirror Experiment Upgrade (TMX-U)
Conference · Wed Nov 13 23:00:00 EST 1985 · OSTI ID:6370484

TMX-axisymmetric magnet set design study
Conference · Wed Dec 31 23:00:00 EST 1980 · Proc. Symp. Eng. Probl. Fusion Res.; (United States) · OSTI ID:6362343