Radio-frequency probe for bubble size and velocity measurements
Journal Article
·
· Rev. Sci. Instrum.; (United States)
A radio frequency (rf) probe that can provide local void fraction and interface velocity measurements in a gas--liquid two-phase flow was developed. The probe response to bubble passage was investigated with single-bubble controlled experiments. For a fixed geometry, the probe response was dependent on the dielectric constant of the medium surrounding the probe tip (air or water) and on the frequency of the carrier signal supplied to the probe. Bubble lengths (< 1 cm) and average bubble approach velocities (< 160 cm/s) were independently measured by two light sources and detectors placed at a known distance from each other and sensing the passage of each bubble. By choosing a sensitive probe tip length of 2.75--3 mm, the rf probe output provided enough information to determine the bubble length and velocity. The results obtained by the two independent methods show reasonable agreement ( +- 10%).
- Research Organization:
- Brookhaven National Laboratory, Thermal Hydraulic Development Division, Department of Nuclear Energy, Upton, New York 11973
- OSTI ID:
- 5915152
- Journal Information:
- Rev. Sci. Instrum.; (United States), Journal Name: Rev. Sci. Instrum.; (United States) Vol. 50:10; ISSN RSINA
- Country of Publication:
- United States
- Language:
- English
Similar Records
Radio frequency (r-f) probe for bubble size and velocity measurements
Response characteristics of optical probes. [PWR]
Void fraction, bubble velocity and bubble size in two-phase flow
Technical Report
·
Wed Feb 28 23:00:00 EST 1979
·
OSTI ID:6099605
Response characteristics of optical probes. [PWR]
Conference
·
Sat Dec 31 23:00:00 EST 1977
·
OSTI ID:6546745
Void fraction, bubble velocity and bubble size in two-phase flow
Journal Article
·
Wed May 01 00:00:00 EDT 1985
· Int. J. Multiphase Flow; (United States)
·
OSTI ID:6192507