SLSF local fault safety experiment P4: summary and conclusions. [Sodium Loop Safety Facility]
Sodium Loop Safety Facility (SLSF) experiment P4 in ETR was performed to investigate the consequences of an upper-bound or worse-than-worst case local fault configuration. P4 was intended to bound the consequences of credible subassembly faults by ejecting molten fuel into a 37-pin bundle of full-length Fast Test Reactor (FTR)-type pins and failing fuel with the potential for further cladding and fuel-pin damage. In addition to ejecting a large amount of molten fuel at or near full power, experiment objectives were to evaluate the severity of molten fuel-coolant interactions (MFCIs) and to demonstrate that any resulting blockage could either be tolerated during continued power operation or detected by global monitors in time to prevent significant fuel failure propagation.
- Research Organization:
- Argonne National Lab., IL (USA)
- DOE Contract Number:
- W-31109-ENG-38
- OSTI ID:
- 5913607
- Report Number(s):
- CONF-850410-14; ON: DE85004025
- Country of Publication:
- United States
- Language:
- English
Similar Records
SLSF in-reactor local fault safety experiment P4. Final report
Review of recent ANL safety experiments in SLSF and TREAT. [LMFBR]
Related Subjects
210500 -- Power Reactors
Breeding
22 GENERAL STUDIES OF NUCLEAR REACTORS
220900* -- Nuclear Reactor Technology-- Reactor Safety
ACCIDENTS
BREEDER REACTORS
ENRICHED URANIUM REACTORS
EPITHERMAL REACTORS
ETR REACTOR
FAST REACTORS
FBR TYPE REACTORS
FFTF REACTOR
FUEL ELEMENT FAILURE
FUEL ELEMENTS
FUEL PINS
IRRADIATION REACTORS
ISOTOPE PRODUCTION REACTORS
LIQUID METAL COOLED REACTORS
LMFBR TYPE REACTORS
MELTDOWN
REACTOR ACCIDENTS
REACTOR COMPONENTS
REACTORS
RESEARCH AND TEST REACTORS
RESEARCH REACTORS
SODIUM COOLED REACTORS
TANK TYPE REACTORS
TEST REACTORS
THERMAL REACTORS
WATER COOLED REACTORS
WATER MODERATED REACTORS