Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

RADLAC-II accelerator pulsed power upgrade results

Conference ·
The completed upgrade of the 20-MeV RADLAC-II linear induction accelerator (LIA) is being evaluated. The upgrade includes improvements in the electron beam energy, current, beam quality, and accelerator reliability. The design goals of 2.5 MV/stage, 40-kA peak current, >40-ns pulse width, >20-ns flattop, and a 1-cm radius annular beam have been met or exceeded by the injector and by the injector plus two accelerating gaps. These results agree with circuit simulation predictions. A description of the accelerator and a comparison of pulsed power experimental measurements with circuit model waveforms are presented. 15 refs., 7 figs., 2 tabs,
Research Organization:
Sandia National Labs., Albuquerque, NM (USA)
DOE Contract Number:
AC04-76DP00789
OSTI ID:
5912752
Report Number(s):
SAND-88-3335C; CONF-890665-24; ON: DE89013565
Country of Publication:
United States
Language:
English