Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Measurements of collisional excitation rate coefficients for Fe X ions in a plasma

Journal Article · · Phys. Rev. A; (United States)
About 1% or more of iron was introduced into a hydrogen-filled theta pinch by a gun-injection method. The Fe X density in the plasma was determined from the measured intensity of the Fe X forbidden (coronal) line at 6374.5 A. Electron collisional excitation rate coefficients for Fe X were obtained from measurements of Fe X vacuum-ultraviolet line intensities, electron density and temperature, and Fe X density. The experimental rate coefficients are compared with theoretical results.
Research Organization:
Laboratory for Plasma and Fusion Energy Studies, University of Maryland, College Park, Maryland 20742
OSTI ID:
5904599
Journal Information:
Phys. Rev. A; (United States), Journal Name: Phys. Rev. A; (United States) Vol. 27:4; ISSN PLRAA
Country of Publication:
United States
Language:
English