Development of the dual-cycle absorption heat pump for residential application. Appendix C: Environment and safety. Final report
Technical Report
·
OSTI ID:5903263
The report identifies from available literature, environmental and toxicity information on selected absorbent-refrigerant compound pairs that potentially could be used in the Battelle Absorption Heat Pump (BAHP). The study indicates that there are no life-threatening effects that might be expected from a heat pump using the candidate fluids (ammonia, and lithium bromide) and operating in a normal environment. Environmental Protection Agency regulations for hazardous waste and a report, Preliminary Safety (Fault Tree) Analysis of Dual Cycle Absorption Heat Pump, are included.
- Research Organization:
- Battelle Columbus Labs., OH (USA)
- OSTI ID:
- 5903263
- Report Number(s):
- PB-91-138537/XAB; CNN: GRI-5083-242-0850
- Resource Relation:
- Other Information: See also PB--91-138529 and PB--91-138545
- Country of Publication:
- United States
- Language:
- English
Similar Records
Development of the dual-cycle absorption heat pump for residential application. Appendix B: Analysis of materials compatibility and corrosion for dual-cycle absorption heat pump. Final report, April 1984-March 1990
Development of the dual-cycle absorption heat pump for residential application. Appendix D: Review of building and mechanical codes and standards for absorption heat pumps. Final report
Development of the dual-cycle absorption heat pump for residential application. Appendix A: Reduced data for key tests of the dual-cycle prototype unit. Final report
Technical Report
·
Sun Apr 01 00:00:00 EST 1990
·
OSTI ID:5903263
Development of the dual-cycle absorption heat pump for residential application. Appendix D: Review of building and mechanical codes and standards for absorption heat pumps. Final report
Technical Report
·
Sun Apr 01 00:00:00 EST 1990
·
OSTI ID:5903263
Development of the dual-cycle absorption heat pump for residential application. Appendix A: Reduced data for key tests of the dual-cycle prototype unit. Final report
Technical Report
·
Sun Apr 01 00:00:00 EST 1990
·
OSTI ID:5903263
Related Subjects
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION
HEAT PUMPS
REFRIGERANTS
ENVIRONMENTAL EFFECTS
TOXICITY
ABSORPTION REFRIGERATION CYCLE
AMMONIA
LITHIUM BROMIDES
PROGRESS REPORT
REGULATIONS
RESIDENTIAL BUILDINGS
SAFETY
US EPA
ALKALI METAL COMPOUNDS
BROMIDES
BROMINE COMPOUNDS
BUILDINGS
DOCUMENT TYPES
FLUIDS
HALIDES
HALOGEN COMPOUNDS
HYDRIDES
HYDROGEN COMPOUNDS
LITHIUM COMPOUNDS
LITHIUM HALIDES
NATIONAL ORGANIZATIONS
NITROGEN COMPOUNDS
NITROGEN HYDRIDES
US ORGANIZATIONS
WORKING FLUIDS
320106* - Energy Conservation
Consumption
& Utilization- Building Equipment- (1987-)
HEAT PUMPS
REFRIGERANTS
ENVIRONMENTAL EFFECTS
TOXICITY
ABSORPTION REFRIGERATION CYCLE
AMMONIA
LITHIUM BROMIDES
PROGRESS REPORT
REGULATIONS
RESIDENTIAL BUILDINGS
SAFETY
US EPA
ALKALI METAL COMPOUNDS
BROMIDES
BROMINE COMPOUNDS
BUILDINGS
DOCUMENT TYPES
FLUIDS
HALIDES
HALOGEN COMPOUNDS
HYDRIDES
HYDROGEN COMPOUNDS
LITHIUM COMPOUNDS
LITHIUM HALIDES
NATIONAL ORGANIZATIONS
NITROGEN COMPOUNDS
NITROGEN HYDRIDES
US ORGANIZATIONS
WORKING FLUIDS
320106* - Energy Conservation
Consumption
& Utilization- Building Equipment- (1987-)