Electromagnetic pulse-induced-current measurement device. Final technical report, Jun 89-Sep 90
Technical Report
·
OSTI ID:5897734
To develop safety guidelines for exposure to high fields associated with an electromagnetic pulse (EMP), it is necessary to devise techniques that would measure the peak current induced in the human body. The main focus of this project was to design, fabricate, and test a portable, self-contained stand-on device that would measure and hold the peak current and the integrated change Q. The design specifications of the EMP-Induced Current Measurement Device are as follows: rise time of the current pulse, 5 ns; peak current, 20-600A; charge Q, 0-20 micro coulomb. The device uses a stand-on parallel-plate bilayer sensor and fast high-frequency circuit that are well-shielded against spurious responses to high incident fields. Since the polarity of the incident peak electric field of the EMP may be either positive or negative, the induced peak current can also be positive or negative. Therefore, the device is designed to respond to either of these polarities and measure and hold both the peak current and the integrated charge which are simultaneously displayed on two separate 3-1/2 digit displays. The prototype device has been preliminarily tested with the EMPs generated at the Air Force Weapons Laboratory (ALECS facility) at Kirtland AFB, New Mexico.
- Research Organization:
- Southeastern Center for Electrical Engineering Education, Inc., St. Cloud, FL (United States)
- OSTI ID:
- 5897734
- Report Number(s):
- AD-A-241946/3/XAB; CNN: F33615-87-D-0609
- Country of Publication:
- United States
- Language:
- English
Similar Records
Final report for EMP instrumentation project DNA IACRO 75-815: magnetic thin film sensors
A study of the charge and current induced on an aircraft in an EMP simulator facility. part i. the formulation. part ii. the singularity expansion method. Part III. The numerical results. Final report
Noninvasive measurement of current for dosimetry. Final report Aug 89-Aug 90
Technical Report
·
Thu Oct 30 23:00:00 EST 1975
·
OSTI ID:4184699
A study of the charge and current induced on an aircraft in an EMP simulator facility. part i. the formulation. part ii. the singularity expansion method. Part III. The numerical results. Final report
Technical Report
·
Tue Nov 30 23:00:00 EST 1976
·
OSTI ID:7214597
Noninvasive measurement of current for dosimetry. Final report Aug 89-Aug 90
Technical Report
·
Fri May 01 00:00:00 EDT 1992
·
OSTI ID:7275771
Related Subjects
45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEFENSE
450200* -- Military Technology
Weaponry
& National Defense-- Nuclear Explosions & Explosives
560400 -- Other Environmental Pollutant Effects
63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTANT EFFECTS ON LIVING ORGS. AND BIOL. MAT.
AMMETERS
ANIMALS
BIOLOGICAL EFFECTS
CURRENTS
DESIGN
DEVELOPED COUNTRIES
ELECTRIC CURRENTS
ELECTRIC FIELDS
ELECTRIC MEASURING INSTRUMENTS
ELECTRICAL EQUIPMENT
ELECTROMAGNETIC PULSES
ELECTROMAGNETIC RADIATION
EQUIPMENT
FABRICATION
FEDERAL REGION VI
FUNCTIONAL MODELS
MAMMALS
MAN
MEASURING INSTRUMENTS
NEW MEXICO
NORTH AMERICA
PERFORMANCE TESTING
PRIMATES
PULSES
RADIATIONS
RECOMMENDATIONS
SAFETY
SPECIFICATIONS
TESTING
USA
VERTEBRATES
450200* -- Military Technology
Weaponry
& National Defense-- Nuclear Explosions & Explosives
560400 -- Other Environmental Pollutant Effects
63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTANT EFFECTS ON LIVING ORGS. AND BIOL. MAT.
AMMETERS
ANIMALS
BIOLOGICAL EFFECTS
CURRENTS
DESIGN
DEVELOPED COUNTRIES
ELECTRIC CURRENTS
ELECTRIC FIELDS
ELECTRIC MEASURING INSTRUMENTS
ELECTRICAL EQUIPMENT
ELECTROMAGNETIC PULSES
ELECTROMAGNETIC RADIATION
EQUIPMENT
FABRICATION
FEDERAL REGION VI
FUNCTIONAL MODELS
MAMMALS
MAN
MEASURING INSTRUMENTS
NEW MEXICO
NORTH AMERICA
PERFORMANCE TESTING
PRIMATES
PULSES
RADIATIONS
RECOMMENDATIONS
SAFETY
SPECIFICATIONS
TESTING
USA
VERTEBRATES