Installation restoration program. Operable Unit B1 remedial investigation/feasibility study. Appendices. Final report

Technical Report ·
OSTI ID:5897681
This document presents the results from the remedial investigation and feasibility study for Operable Unit (OU) B1 at McClellan AFB, Sacramento, CA. Operable Unit B1 includes the Defense Reutilization and Marketing Office (DRMO) storage lot and Civil Engineering storage lot at McClellan AFB. The main chemicals of concern are PCBs, dioxins, and furans which may have leaked from transformers stored at OU B1 or were constituents of waste oil applied to soils to control dust. Sections 1.0 through 4.0 of the report present results from the RI, the potential for contaminant migration/transport from OU B1 and the current and future risks associated with OU B1. The FS begins in Section 5.0 identifying the remedial action objectives, in Sections 6.0 and 7.0, technologies are screened and potential remedial alternatives are developed. The final six remedial alternatives are analyzed and compared to each other using the criteria established in the NCP in Section 8.0.
Research Organization:
Radian Corp., Sacramento, CA (United States)
OSTI ID:
5897681
Report Number(s):
AD-A-266947/1/XAB
Country of Publication:
United States
Language:
English