LDA measurement of turbulent flow in a motored and firing spark-ignition engine with a horizontal prechamber

Conference ·
OSTI ID:5892965
To make clear the influence of a torch jet flow on the combustion process, a laser Doppler anemometer (LDA) is used to measure the mean velocity and turbulence intensity in a spark ignition engine with an unscavenged prechamber connected to a main chamber by a torch nozzle of different area sizes. The test engine is operated at a constant speed of 16.7 rps (1000 rpm), a constant volumetric efficiency of 80 +- 2% and MBT for each torch nozzle ara under firing as well as motored conditions. The LDA system is a dual beam forward scatter type, and its signals are acquired quickly and stored in a memory through a frequency tracking system.