Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Position resolution of a gas counter in the SQS transition region

Conference · · IEEE Trans. Nucl. Sci.; (United States)
OSTI ID:5892073
Position resolutions around the transition region from the proportional to self-quenching streamer (SQS) modes in a gas counter has been measured. The counter used is of a strip-cathode type, which is filled with a mixed gas Ar70% + CH/sub 4/30% adding an adequate concentration of ethanol. Transistion in the position resolution was clearly observed between the SQS mode and the double SQS mode in any concentration of the ethanol, while not so clearly between the proportional mode and the SQS mode. The best position resolution, 0.11mm (FWHM), was obtained in the double SQS mode operation.
Research Organization:
Dept. of Energy Conversion Eng., Graduate School of Eng. Sciences, Kyushu Univ., Kasuga 816
OSTI ID:
5892073
Report Number(s):
CONF-851009-
Conference Information:
Journal Name: IEEE Trans. Nucl. Sci.; (United States) Journal Volume: NS-33:1
Country of Publication:
United States
Language:
English

Similar Records

Position sensing with magic gas mixture in the transition region from the proportional to the self-quenching streamer mode
Conference · Tue Jan 31 23:00:00 EST 1989 · IEEE Trans. Nucl. Sci.; (United States) · OSTI ID:6285029

Dead zone characteristics of SQS and GM modes in Kr-, Ar- and Ne-Mixtures
Conference · Sat Aug 01 00:00:00 EDT 1992 · IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (United States) · OSTI ID:6730900

Use of electroluminescence of gas mixtures for optical data acquisition from wire chambers
Journal Article · Fri Jul 01 00:00:00 EDT 1988 · Instrum. Exp. Tech. (Engl. Transl.); (United States) · OSTI ID:6473381