Laboratory investigations of cascade crossflow packed towers for air stripping of volatile organics from ground-water. Final report, 21 Apr 86-24 Aug 89

Technical Report ·
OSTI ID:5892002

This report evaluates the effectiveness of a cascade crossflow air stripper for the removal of Volatile Organic Compounds (VOCs) from simulated groundwater. Experimental tests were conducted on four VOCs-methylene chloride, chloroform, 1,2-dichloroethane and carbon tetrachloride - on both a 6-inch internal diameter laboratory scale column and a 12-inch internal diameter pilot-scale column. The additional variable, alpha, which is the ratio of gas to liquid flow areas was investigated. Experimental data on stripping efficiencies were used to obtain mass transfer coefficients in crossflow operation. These mass transfer coefficients were compared with literature correlations obtained for conventional countercurrent operation, but modified appropriately for crossflow. For liquid phase controlled chemicals, the modified Onda's correlation satisfactorily predicted the crossflow mass transfer coefficient.

Research Organization:
Louisiana State Univ., Baton Rouge, LA (United States). Dept. of Chemical Engineering
OSTI ID:
5892002
Report Number(s):
AD-A-242496/8/XAB; CNN: F08635-86-C-0159
Country of Publication:
United States
Language:
English