Measurements of gamma-ray dose from a moderated /sup 252/Cf source
The gamma-ray dose fraction from a moderated /sup 252/Cf source was determined by using three types of dosimetry systems. Measurements were carried out in air at a distance of 35 cm from the surface of the moderating sphere (50 cm from the source which is at the center of the sphere) to the geometrical center of each detector. The moderating sphere is 0.8-mm-thick stainless steel shell filled with D/sub 2/O and covered with 0.5 mm of cadmium. Measurements were also carried out with instruments and dosimeters positioned at the surface of a 40 cm x 40 cm x 15 cm plexiglass irradiation phantom whose front surface was also 35 cm from the surface of the moderating sphere. A-150 tissue-equivalent (TE) plastic ionization chambers and a TE proportional counter (TEPC) were used to measure tissue dose, from which the neutron dose equivalent was computed. The ratio of gamma-ray dose to the neutron dose equivalent was determined by using a relatively neutron-insensitive Geiger-Mueller (GM) counter and thermoluminescent dosimeters (TLD). In addition, the event-size spectrum measured by the TEPC was also used to compute the gamma-ray dose fraction. The average value for the ratio of gamma-ray dose to neutron dose equivalent was found to be 0.18 with an uncertainty of about +-18%.
- Research Organization:
- Pacific Northwest Lab., Richland, WA (USA)
- DOE Contract Number:
- AC06-76RL01830
- OSTI ID:
- 5891880
- Report Number(s):
- NUREG/CR-2957; PNL-4590; ON: DE83015437
- Country of Publication:
- United States
- Language:
- English
Similar Records
Development of a tissue-equivalent proportional-counter system for the measurement of neutron dose. Final report, 1986-1987
Neutron dose and energy spectra measurements at Savannah River Plant
VALIDATION OF HANFORD PERSONNEL AND EXTREMITY DOSIMETERS IN PLUTONIUM ENVIRONMENTS
Technical Report
·
Tue May 19 00:00:00 EDT 1987
·
OSTI ID:6380428
Neutron dose and energy spectra measurements at Savannah River Plant
Technical Report
·
Sat Aug 01 00:00:00 EDT 1987
·
OSTI ID:5853354
VALIDATION OF HANFORD PERSONNEL AND EXTREMITY DOSIMETERS IN PLUTONIUM ENVIRONMENTS
Technical Report
·
Wed Feb 09 23:00:00 EST 2000
·
OSTI ID:968960
Related Subjects
61 RADIATION PROTECTION AND DOSIMETRY
655003* -- Medical Physics-- Dosimetry
ACTINIDE ISOTOPES
ACTINIDE NUCLEI
ALPHA DECAY RADIOISOTOPES
BARYONS
CALIFORNIUM 252
CALIFORNIUM ISOTOPES
DATA
DOSE EQUIVALENTS
DOSEMETERS
DOSIMETRY
ELEMENTARY PARTICLES
EVEN-EVEN NUCLEI
EXPERIMENTAL DATA
FERMIONS
GAMMA DOSIMETRY
GAMMA SOURCES
HADRONS
HEAVY NUCLEI
INFORMATION
ISOTOPES
LUMINESCENT DOSEMETERS
MEASURING INSTRUMENTS
MOCKUP
NEUTRONS
NUCLEI
NUCLEONS
NUMERICAL DATA
PHANTOMS
PROPORTIONAL COUNTERS
RADIATION DETECTORS
RADIATION SOURCES
RADIOISOTOPES
STRUCTURAL MODELS
THERMOLUMINESCENT DOSEMETERS
YEARS LIVING RADIOISOTOPES
655003* -- Medical Physics-- Dosimetry
ACTINIDE ISOTOPES
ACTINIDE NUCLEI
ALPHA DECAY RADIOISOTOPES
BARYONS
CALIFORNIUM 252
CALIFORNIUM ISOTOPES
DATA
DOSE EQUIVALENTS
DOSEMETERS
DOSIMETRY
ELEMENTARY PARTICLES
EVEN-EVEN NUCLEI
EXPERIMENTAL DATA
FERMIONS
GAMMA DOSIMETRY
GAMMA SOURCES
HADRONS
HEAVY NUCLEI
INFORMATION
ISOTOPES
LUMINESCENT DOSEMETERS
MEASURING INSTRUMENTS
MOCKUP
NEUTRONS
NUCLEI
NUCLEONS
NUMERICAL DATA
PHANTOMS
PROPORTIONAL COUNTERS
RADIATION DETECTORS
RADIATION SOURCES
RADIOISOTOPES
STRUCTURAL MODELS
THERMOLUMINESCENT DOSEMETERS
YEARS LIVING RADIOISOTOPES